Physiotherapy Machine is a high-power therapeutic laser system designed for professional physiotherapy, rehabilitation, pain management, and sports therapy applications. It delivers controlled laser energy to targeted areas and may support deep-tissue therapeutic treatments. Models commonly offer continuous and pulsed modes, adjustable power, touch-screen controls, and different wavelength options.
Handheld Laser Device with TENS
General Introduction
Laser therapy delivers non-thermal photons of light to the body for about 3-8 minutes by injured cells. The cells are then stimulated and respond with a higher rate of metabolism. This results in relief from pain, better circulation, anti-inflammation, and acceleration of the healing process.
Results vary from patient to patient and most are enjoying life again within a few weeks. The result of low intensity laser irradiation is the restoration of normal function of the cell unit.
TENS device adopts gentle electrical impulse which can stop the pain signals going to your brain and naturally enables your body to release endorphins, the body's 'feel good' chemical.
TENS is used as a natural pain reliever and is ideal for chronic pain, sore muscles, fatigue reduction and tension release.
The low frequency electric can be adjusted to 3 levels between 40-200Hz. By means of this, it may successfully assist in the promotion of improving blood circulation and the acceleration of tissue regeneration.
The regular application of these treatments assists in jump starting the micro-circulation, as a result of which bones and joints receive a higher level of protection. Furthermore, each and every cell type receives the energy required for its optimal functioning in the body, which facilitates wound healing and pain relief.
Therapy Application
- Pain relief
- Knee arthritis
- Joints and bones injuries
- Soft tissue injuries
- Athletics system injuries
- Sports injuries & Sprain
- Wounds & Ulcer acupuncture
- Anti-inflammation
Treatment Principle
What's Red Light?
Red light resides on the visible end of the spectrum, which means you can see it. It is, however, on the "long end" of the whole spectrum in general.
Red light waves are the longest wavelengths that are still visible to human eyes. The longer wavelength of red light is the more effective it is for penetrating your body to a significant cellular level. Short red light penetrates your body to a depth of about 8 to 10 millimeters, reaching the mitochondria of your skin cells and other cells that are located closely beneath your skin to stimulate biological reaction.
Red light therapy is a form of photo bio-modulation or a treatment that uses light-emitting diodes (LED) or low-level laser therapy (LLLT) to stimulate cellular activity to achieve therapeutic benefits.
Key Mechanisms of Red/NIR Light Therapy
Generally speaking, red/NIR light has two central mechanisms in how it benefits cellular function and overall health:
- Stimulating ATP production in the mitochondria through interacting with a photoreceptor called cytochrome c oxidase.
- Creating a temporary, low-dose metabolic stress (known as hormesis, which is also a primary mechanism of why exercise works) that ultimately builds up the anti-inflammatory, anti-oxidant and cell defense systems of the cell.
Obviously, red light is best suited for treating skin conditions, local pain, mild inflammation, and accelerating surface wounds healing.
And what is trustworthy is that there are no adverse side effects. Red light does not create heat, although you might experience a mild and pleasant warm sensation on your skin during therapy, but it won't burn your skin or damage any underlying body tissues.
It has been proven that almost all wavelengths of red light will provide a sort of benefits, but wavelength from 650nm to 850nm demonstrate the most healing power.
Instructions
Wearing
Put unit into holder, and then fix it with body's area that you need to treat.
By the way, it is better to put cream on body for more comfortable treatment.
Using Guide
General, the device can be used several times per day, until the problem ceases. We would recommend using this device twice per day, 20 minutes for each time, 10-15 days for one treatment session, 2-3 days' interval before next session. Please adjust the usage time according to your own conditions.
Long-term application does not have side effects. Please consult physician in the case of a special problem, before commencing regular use or a treatment course!
The device is safe and reliable, its operation is simple and convenient, its effect is evident, at the same time it is such a complementary treatment device that does not cause scarring.
Main Technical Specifications
| Laser Medium |
GaAlAs Semiconductor |
| Laser Wavelength |
650nm ± 20nm / 808nm ± 20nm |
| Number of Laser Diodes |
6 × 650nm + 6 × 808nm |
| Maximum Output Power per 808nm Laser Diode |
150mW ± 20% |
| Maximum Output Power per 808nm Laser Diode |
5mW ± 20% |
| Total Laser Power |
930mW |
| Laser Power |
3 levels (First level: pulse, Second and Third level: constant) |
| TENS Power |
3 levels |
| Time Setting |
5-30 minutes, 5 minutes as an interval |
| Battery Voltage |
DC3.7V |
| Battery Capacity |
2600mAh |
| Input Power |
< 10VA |
| Environmental Temperature |
5°C - 40°C |
| Relative Humidity |
≤ 80% |
| Atmospheric Pressure |
860hpa - 1060hpa |
| Voltage |
100-240V |